A fuel pump relay bypass can run a pump independently of its normal command on certain circuits, but there is no safe universal jumper position. Use the vehicle wiring diagram and prescribed test equipment. Where supported, a bidirectional scan-tool activation is preferable because it can command the installed control system without guessing relay terminals.
Do not use a bypass to keep driving, defeat a collision shutoff or force a leaking system to run. “Jump-starting the pump” and “manually turning it on” describe the same basic diagnostic concern: supplying or commanding operation outside the normal starting sequence. Neither repairs the underlying fault.
Identify the control architecture first
Some vehicles use a removable relay; others use a module, a solid-state output or variable-speed control. A relay shown in a diagram may supply a controller rather than feed the motor directly. The existence of a relay-shaped part in a fuse box does not establish how its socket is wired.
Read the circuit for the exact model and engine. Identify the pump feed, control path, protection devices and conditions for activation. Without that information, a jumper can put battery voltage onto a control circuit or bridge the wrong part of the system.

Credit: www.youtube.com
Understand why a quiet pump may be normal
The pump may operate briefly at key-on and then stop until the required engine or control signal is present. Ford’s fuel-pump control description, for the system it covers, describes a short initial command and an inertia-switch interruption in the delivery circuit. Its timing and arrangement are not universal.
A measurement taken after a prime interval can therefore show no command even though the control system behaved correctly. Establish when the pump should run before treating silence, a dark test lamp or zero voltage at one moment as evidence of a defect.
Use a supported commanded test where available
A suitable bidirectional tool can request fuel-pump operation if that function is supported by the vehicle and permitted under the current conditions. Confirm the tool’s function is an actual output test, not simply a display of commanded duty cycle. Follow its precautions, duration and shutdown instructions.
The command alone does not prove delivery. Observe the response using the prescribed pressure, flow or electrical measurement. If the request is rejected, investigate the stated prerequisites or fault conditions instead of assuming that the pump motor has failed.

Credit: verticalvisions.com
Why this guide does not give a terminal-number recipe
A familiar relay numbering pattern is not proof of socket orientation, internal suppression components or the circuit role of each cavity. A photograph from another vehicle is even less reliable. The service procedure must identify the exact terminals and whether a fused bypass is permitted for that test.
When a bypass is explicitly specified, a trained technician uses correctly rated, fused equipment and suitable terminal adapters, with the circuit closed and fuel contained. Loose wire, paper clips and oversized probes can short adjacent terminals or damage socket contacts. Improvised power connections near fuel vapor add an ignition source.
Interpret the result without overclaiming
If controlled activation makes the pump run, you have shown it can operate in that particular electrical state. You have not proved the relay is faulty, that pressure and flow are sufficient, or that the original control command was missing for the wrong reason. The command may have been intentionally withheld.

Credit: www.youtube.com
If the pump stays silent, the result still needs interpretation: the test connection, fuse, power supply, ground, wiring and motor are all possible areas to investigate. A sound from the tank is not a substitute for the delivery measurement required by the diagnostic procedure.
Follow the fault back through the circuit
Compare commanded operation, power at the load and the ground path under appropriate load. Delphi’s voltage-drop guidance explains why poor supply or ground connections can make a pump underperform. A shortcut that feeds power somewhere else can conceal that original connection fault.
Record whether the abnormality is in command, relay switching, feed, ground or measured delivery. If you are checking a conventional relay with a lamp, the separate test-light guide explains which circuits must not be probed indiscriminately.
Restore normal control before operating the vehicle
Remove diagnostic jumpers and adapters, restore the correct relay and connector retention, and verify the original fault with the system in its normal configuration. A running engine with a temporary bridge fitted is not a completed repair.
If normal operation cannot be restored, arrange recovery rather than drive with a forced-on pump. The final evidence should show that the system commands and stops the pump as intended and that fuel delivery meets the vehicle specification—not merely that a temporary power feed made it audible.

